Showing posts with label Power System. Show all posts
Showing posts with label Power System. Show all posts

Monday, 18 May 2015

Gas Turbine Power Plant

Gas Turbine Power Plant

A generating station which employs gas turbine as the prime mover for the generation of electrical
energy is known as a gas turbine power plant

In a gas turbine power plant, air is used as the working fluid. The air is compressed by the compressor and is led to the combustion chamber where heat is added to air, thus raising its temperature. Heat is added to the compressed air either by burning fuel in the chamber or by the use of air heaters. The hot and high pressure air from the combustion chamber is then passed to the gas turbine where it expands and does the mechanical work. The gas turbine drives the alternator which converts mechanical energy into electrical energy.

It may be mentioned here that compressor, gas turbine and the alternator are mounted on the same shaft so that a part of mechanical power of the turbine can be utilised for the operation of the compressor. Gas turbine power plants are being used as standby plants for hydro-electric stations, as a starting plant for driving auxiliaries in power plants etc.

Advantages
(i) It is simple in design as compared to steam power station since no boilers and their auxiliaries are required.
(ii) It is much smaller in size as compared to steam power station of the same capacity. This is expected since gas turbine power plant does not require boiler, feed water arrangement etc.

(iii) The initial and operating costs are much lower than that of equivalent steam power station.
(iv) It requires comparatively less water as no condenser is used.
(v) The maintenance charges are quite small.
(vi) Gas turbines are much simpler in construction and operation than steam turbines.
(vii) It can be started quickly form cold conditions.
(viii) There are no standby losses. However, in a steam power station, these losses occur because boiler is kept in operation even when the steam turbine is supplying no load.

Disadvantages
(i) There is a problem for starting the unit. It is because before starting the turbine, the compressor has to be operated for which power is required from some external source. However, once the unit starts, the external power is not needed as the turbine itself supplies the necessary power to the compressor.
(ii) Since a greater part of power developed by the turbine is used in driving the compressor, the net output is low.
(iii) The overall efficiency of such plants is low (about 20%) because the exhaust gases from the turbine contain sufficient heat.
(iv) The temperature of combustion chamber is quite high (3000oF) so that its life is comparatively reduced.

Schematic Arrangement of Gas Turbine Power Plant

The schematic arrangement of a gas turbine power plant is shown in . The main components
of the plant are :
(i) Compressor (ii) Regenerator (iii)Combustion chamber (iv) Gas turbine (v) Alternator (vi) Starting motor

(i) Compressor.  The compressor used in the plant is generally of rotatory type. The air at atmospheric pressure is drawn by the compressor viathe filter which removes the dust from air. The rotatory blades of the compressor push the air between stationary blades to raise its pressure. Thus air at high pressure is available at the output of the compressor.

(ii) Regenerator. A regenerator is a device which recovers heat from the exhaust gases of the turbine. The exhaust is passed through the regenerator before wasting to atmosphere. A regenerator consists of a nest of tubes contained in a shell. The compressed air from the compressor passes through the tubes on its way to the combustion chamber. In this way, compressed air is heated by the hot exhaust gases.

(iii) Combustion chamber. The air at high pressure from the compressor is led to the combustion chamber viathe regenerator. In the combustion chamber, heat*is added to the air by burning oil. The oil is injected through the burner into the chamber at high pressure to ensure atomisation of oil and its thorough mixing with air. The result is that the chamber attains a very high temperature (about 3000oF). The combustion gases are suitably cooled to 1300o F to 1500o F and then delivered to the gas turbine.

(iv) Gas turbine. The products of combustion consisting of a mixture of gases at high temperature and pressure are passed to the gas turbine. These gases in passing over the turbine blades expand and thus do the mechanical work. The temperature of the exhaust gases from the turbine is about 900oF.

(v) Alternator. The gas turbine is coupled to the alternator. The alternator converts mechanical energy of the turbine into electrical energy. The output from the alternator is given to the bus-bars through transformer, circuit breakers and isolators.
(vi) Starting motor. Before starting the turbine, compressor has to be started. For this purpose, an electric motor is mounted on the same shaft as that of the turbine. The motor is energised by the batteries. Once the unit starts, a part of mechanical power of the turbine drives the compressor and there is no need of motor now.

Introduction To Nuclear Power Station

Nuclear Power Station


A generating station in which nuclear energy is converted into electrical energy is known as a nuclear power station.
In nuclear power station, heavy elements such as Uranium (U235) or Thorium (Th232) are subjected to nuclear fission.  in a special apparatus known as a reactor.The heat energy thus released is utilised in raising steam at high temperature and pressure. The steam runs the steam turbine which converts steam energy into mechanical energy. The turbine drives the alternator which converts mechanical energy into electrical energy.
The most important feature of a nuclear power station is that huge amount of electrical energy can be produced from a relatively small amount of nuclear fuel as compared to other conventional types of power stations. It has been found that complete fission of 1 kg of Uranium (U235) can produce as much energy as can be produced by the burning of 4,500 tons of high grade coal. Although the recovery of principal nuclear fuels (i.e., Uranium and Thorium) is difficult and expensive, yet the total energy content of the estimated world reserves of these fuels are considerably higher than those of conventional fuels, viz., coal, oil and gas.

At present, energy crisis is gripping us and, therefore, nuclear energy can be successfully employed for producing low cost electrical energy on a large scale to meet the growing commercial and industrial demands.

Advantages
(i) The amount of fuel required is quite small. Therefore, there is a considerable saving in the cost of fuel transportation.
(ii) A nuclear power plant requires less space as compared to any other type of the same size.
(iii) It has low running charges as a small amount of fuel is used for producing bulk electrical energy.
(iv) This type of plant is very economical for producing bulk electric power.
(v) It can be located near the load centres because it does not require large quantities of water and need not be near coal mines. Therefore, the cost of primary distribution is reduced.
(vi) There are large deposits of nuclear fuels available all over the world. Therefore, such plants can ensure continued supply of electrical energy for thousands of years.
(vii) It ensures reliability of operation.

Disadvantages
(i) The fuel used is expensive and is difficult to recover.
(ii) The capital cost on a nuclear plant is very high as compared to other types of plants.
(iii) The erection and commissioning of the plant requires greater technical know-how.
(iv) The fission by-products are generally radioactive and may cause a dangerous amount of radioactive pollution
(v) Maintenance charges are high due to lack of standardisation. Moreover, high salaries of specially trained personnel employed to handle the plant further raise the cost.
(vi) Nuclear power plants are not well suited for varying loads as the reactor does not respond to the load fluctuations efficiently.
(vii) The disposal of the by-products, which are radioactive, is a big problem. They have either to be disposed off in a deep trench or in a sea away from sea-shore.

Schematic Arrangement of Nuclear Power Station

The schematic arrangement of a nuclear power station is shown in Fig.. The whole arrangement can be divided into the following main stages :
(i) Nuclear reactor (ii) Heat exchanger (iii) Steam turbine (iv) Alternator.

(i) Nuclear reactor.  It is an apparatus in which nuclear fuel (U 235 ) is subjected to nuclear fission. It controls the chain reaction that starts once the fission is done. If the chain reaction is not controlled, the result will be an explosion due to the fast increase in the energy released.
A nuclear reactor is a cylindrical stout pressure vessel and houses fuel rods of Uranium, moderator and control rods . The fuel rods constitute the fission material and release huge amount of energy when bombarded with slow moving neutrons. The moderator consists of graphite rods which enclose the fuel rods. The moderator slows down the neutrons before they bombard the fuel rods. The control rods are of cadmium and are inserted into the reactor. Cadmium is strong neutron absorber and thus regulates the supply of neutrons for fission. When the control rods are pushed in deep enough, they absorb most of fission neutrons and hence few are available for chain reaction which, therefore, stops.

However, as they are being withdrawn, more and more of these fission neutrons cause fission and hence the intensityof chain reaction (or heat produced) is increased. Therefore, by pulling out the control rods, power of the nuclear reactor is increased, whereas by pushing them in, it is reduced. In actual practice, the lowering or raising of control rods is accomplished automatically according to the requirement of load. The heat produced in the reactor is removed by the coolant, generally a sodium metal. The coolant carries the heat to the heat exchanger

(ii) Heat exchanger. The coolant gives up heat to the heat exchanger which is utilised in raising the steam. After giving up heat, the coolant is again fed to the reactor

(iii) Steam turbine. The steam produced in the heat exchanger is led to the steam turbine through a valve. After doing a useful work in the turbine, the steam is exhausted to condenser. The condenser condenses the steam which is fed to the heat exchanger through feed water pump.

(iv) Alternator. The steam turbine drives the alternator which converts mechanical energy into electrical energy. The output from the alternator is delivered to the bus-bars through transformer, circuit breakers and isolators.

Selection of Site for Nuclear Power Station

The following points should be kept in view while selecting the site for a nuclear power station :

(i) Availability of water.  As sufficient water is required for cooling purposes, therefore, the plant site should be located where ample quantity of water is available, e.g., across a river or by sea-side.

(ii) Disposal of waste.  The waste produced by fission in a nuclear power station is generally radioactive which must be disposed off properly to avoid health hazards. The waste should either be buried in a deep trench or disposed off in sea quite away from the sea shore. Therefore, the site selected for such a plant should have adequate arrangement for the disposal of radioactive waste.

(iii) Distance from populated areas.  The site selected for a nuclear power station should be quite away from the populated areas as there is a danger of presence of radioactivity in the atmosphere near the plant. However, as a precautionary measure, a domeis used in the plant which does not allow the radioactivity to spread by wind or underground waterways.

(iv) Transportation facilities. The site selected for a nuclear power station should have adequate facilities in order to transport the heavy equipment during erection and to facilitate the movement of the workers employed in the plant. From the above mentioned factors it becomes apparent that ideal choice for a nuclear power station would be near sea or river and away from thickly populated areas.


What is Diesel Power Station

Diesel Power Station

A generating station in which diesel engine is used as the prime mover for the generation of electrical energy is known as diesel power station.

In a diesel power station, diesel engine is used as the prime mover. The diesel burns inside the engine and the products of this combustion act as the “working fluid” to produce mechanical energy. The diesel engine drives the alternator which converts mechanical energy into electrical energy. As the generation cost is considerable due to high price of diesel, therefore, such power stations are only used to produce small power.

Although steam power stations and hydro-electric plants are invariably used to generate bulk power at cheaper cost, yet diesel power stations are finding favour at places where demand of power is less, sufficient quantity of coal and water is not available and the transportation facilities are inadequate. These plants are also used as standby sets for continuity of supply to important points such as hospitals, radio stations, cinema houses and telephone exchanges.

Advantages
(i) The design and layout of the plant are quite simple.
(ii) It occupies less space as the number and size of the auxiliaries is small.
(iii) It can be located at any place.
(iv) It can be started quickly and can pick up load in a short time.
(v) There are no standby losses.
(vi) It requires less quantity of water for cooling.
(vii) The overall cost is much less than that of steam power station of the same capacity.
(viii) The thermal efficiency of the plant is higher than that of a steam power station.
(ix) It requires less operating staff.

Disadvantages
(i) The plant has high running charges as the fuel (i.e., diesel) used is costly.
(ii) The plant does not work satisfactorily under overload conditions for a longer period.
(iii)The plant can only generate small power.
(iv) The cost of lubrication is generally high.
(v) The maintenance charges are generally high.

Schematic Arrangement of Diesel Power Station

Fig. shows the schematic arrangement of a typical diesel power station. Apart from the dieselgenerator set, the plant has the following auxiliaries :
Diesel Power Station

(i) Fuel supply system. It consists of storage tank, strainers, fuel transfer pump and all day fuel tank. The fuel oil is supplied at the plant site by rail or road. This oil is stored in the storage tank. From the storage tank, oil is pumped to smaller all day tank at daily or short intervals. From this tank, fuel oil is passed through strainers to remove suspended impurities. The clean oil is injected into the engine by fuel injection pump.

(ii) Air intake system.  This system supplies necessary air to the engine for fuel combustion. It consists of pipes for the supply of fresh air to the engine manifold. Filters are provided to remove dust particles from air which may act as abrasive in the engine cylinder.

(iii) Exhaust system.  This system leads the engine exhaust gas outside the building and discharges it into atmosphere. A silencer is usually incorporated in the system to reduce the noise level.

(iv) Cooling system. The heat released by the burning of fuel in the engine cylinder is partially converted into work. The remainder part of the heat passes through the cylinder walls, piston, rings etc. and may cause damage to the system. In order to keep the temperature of the engine parts within the safe operating limits, cooling is provided. The cooling system consists of a water source, pump and cooling towers. The pump circulates water through cylinder and head jacket. The water takes away heat form the engine and itself becomes hot. The hot water is cooled by cooling towers and is recirculated for cooling.

(v) Lubricating system. This system minimises the wear of rubbing surfaces of the engine. It comprises of lubricating oil tank, pump, filter and oil cooler. The lubricating oil is drawn from the lubricating oil tank by the pump and is passed through filters to remove impurities. The clean lubricating oil is delivered to the points which require lubrication. The oil coolers incorporated in the system keep the temperature of the oil low.
(vi) Engine starting system.  This is an arrangement to rotate the engine initially, while starting, until firing starts and the unit runs with its own power. Small sets are started manually by handles but for larger units, compressed air is used for starting. In the latter case, air at high pressure is admitted to a few of the cylinders, making them to act as reciprocating air motors to turn over the engine shaft. The fuel is admitted to the remaining cylinders which makes the engine to start under its own power

Thursday, 14 May 2015

Equipment Of Hydro Power Plant

Equipment Of Hydro Power PlantConstituents of Hydro-electric Plant

The constituents of a hydro-electric plant are (1)hydraulic structures (2) water turbines and
(3)electrical equipment. We shall discuss these items in turn.

1. Hydraulic structures.  Hydraulic structures in a hydro-electric power station include dam, spillways, headworks, surge tank, penstock and accessory works.

Must Read: Equipment of steam power plant

(i) Dam. A dam is a barrier which stores water and creates water head. Dams are built of concrete or stone masonary, earth or rock fill. The type and arrangement depends upon the topography of the site. A masonary dam may be built in a narrow canyon. An earth dam may be best suited for a wide valley. The type of dam also depends upon the foundation conditions, local materials and transportation available, occurrence of earthquakes and other hazards. At most of sites, more than one type of dam may be suitable and the one which is most economical is chosen.

(ii) Spillways.  There are times when the river flow exceeds the storage capacity of the reservoir. Such a situation arises during heavy rainfall in the catchment area. In order to discharge the surplus water from the storage reservoir into the river on the down-stream side of the dam, spillways are used. Spillways are constructed of concrete piers on the top of the dam. Gates are provided between these piers and surplus water is discharged over the crest of the dam by opening these gates.

(iii) Headworks.  The headworks consists of the diversion structures at the head of an intake. They generally include booms and racks for diverting floating debris, sluices for by-passing debris and sediments and valves for controlling the flow of water to the turbine. The flow of water into and through headworks should be as smooth as possible to avoid head loss and cavitation. For this purpose, it is necessary to avoid sharp corners and abrupt contractions or enlargements.
Surge tank.
(iv) Surge tank. Open conduits leading water to the turbine require no*protection. However, when closed conduits are used, protection becomes necessary to limit the abnormal pressure in the conduit. For this reason, closed conduits are always provided with a surge tank. A surge tank is a small reservoir or tank (open at the top) in which water level rises or falls to reduce the pressure swings in the conduit. A surge tank is located near the beginning of the conduit. When the turbine is running at a steady load, there are no surges in the flow of water through the conduit i.e., the quantity of water flowing in the conduit is just sufficient to meet the turbine requirements. However, when the load on the turbine decreases, the governor closes the gates of turbine, reducing water supply to the turbine. The excess water at the lower end of the conduit rushes back to the surge tank and increases its water level. Thus the conduit is prevented from bursting. On the other hand, when load on the turbine increases, additional water is drawn from the surge tank to meet the increased load requirement. Hence, a surge tank overcomes the abnormal pressure in the conduit when load on the turbine falls and acts as a reservoir during increase of load on the turbine.
 (v) Penstocks. Penstocks are open or closed conduits which carry water to the turbines. They are generally made of reinforced concrete or steel. Concrete penstocks are suitable for low heads (< 30 m) as greater pressure causes rapid deterioration of concrete. The steel penstocks can be designed for any head; the thickness of the penstock increases with the head or working pressure. Various devices such as automatic butterfly valve, air valve and surge tank are provided for the protection of penstocks. Automatic butterfly valve shuts off water flow through the penstock promptly if it ruptures. Air valve maintains the air pressure inside the penstock equal to outside atmospheric pressure. When water runs out of a penstock faster than it enters, a vacuum is created which may cause the penstock to collapse. Under such situations, air valve opens and admits air in the penstock to maintain inside air pressure equal to the outside air pressure.

2. Water turbines. Water turbines are used to convert the energy of falling water into mechanical energy. The principal types of water turbines are :
(i) Impulse turbines (ii) Reaction turbines
(i) Impulse turbines. Such turbines are used for high heads. In an impulse turbine, the entire pressure of water is converted into kinetic energy in a nozzle and the velocity of the jet drives the wheel. The example of this type of turbine is the Pelton wheel  It consists of a wheel fitted with elliptical buckets along its periphery. The force of water jet striking the buckets on the wheel drives the turbine. The quantity of water jet falling on the turbine is controlled by means of a needle or spear  placed in the tip of the nozzle. The movement of the needle is controlled by the governor. If the load on the turbine decreases, the governor pushes the needle
into the nozzle, thereby reducing the quantity of water striking the buckets. Reverse action takes place if the
load on the turbine increases.
(ii) Reaction turbines.  Reaction turbines are used for low and medium heads. In a reaction turbine, water enters the runner partly with pressure energy and partly with velocity head. The important types of reaction turbines are :
(a) Francis turbines (b) Kaplan turbines
A Francis turbine is used for low to medium heads. It consists of an outer ring of stationary guide blades fixed to the turbine casing and an inner ring of rotating blades forming the runner. The guide blades control the flow of water to the turbine. Water flows radially inwards and changes to a downward direction while passing through the runner. As the water passes over the “rotating blades” of the runner, both pressure and velocity of water are reduced. This causes a reaction force which drives the turbine.
A Kaplan turbine is used for low heads and large quantities of water. It is similar to Francis turbine except that the runner of Kaplan turbine receives water axially. Water flows radially inwards through regulating gates all around the sides, changing direction in the runner to axial flow. This causes a reaction force which drives the turbine.
3. Electrical equipment. The electrical equipment of a hydro-electric power station includes alternators, transformers, circuit breakers and other switching and protective devices.

Hydro Power Station

Hydro Power Station
Hydro-electric Power Station
A generating station which utilises the potential energy of water at a high level for the generation of electrical energy is known as a hydro-electric power station. Hydro-electric power stations are generally located in hilly areas where dams can be built conveniently and large water reservoirs can be obtained. In a hydro-electric power station, water head is created by constructing a dam across a river or lake. From the dam, water is led to a water turbine.

The water turbine captures the energy in the falling water and changes the hydraulic energy (i.e., product of head and flow of water) into mechanical energy at the turbine shaft. The turbine drives the alternator which converts mechanical energy into electrical energy. Hydro-electric power stations are becoming very popular because the reserves of fuels (i.e., coal and oil) are depleting day by day.
They have the added importance for flood control, storage of water for irrigation and water for drinking purposes.
Advantages
(i) It requires no fuel as water is used for the generation of electrical energy.
(ii) It is quite neat and clean as no smoke or ash is produced.
(iii) It requires very small running charges because water is the source of energy which is available free of cost.
(iv) It is comparatively simple in construction and requires less maintenance.
(v) It does not require a long starting time like a steam power station. In fact, such plants can be put into service instantly.
(vi) It is robust and has a longer life.
(vii) Such plants serve many purposes. In addition to the generation of electrical energy, they also help in irrigation and controlling floods.
(viii) Although such plants require the attention of highly skilled persons at the time of construction, yet for operation, a few experienced persons may do the job well.
Disadvantages
(i) It involves high capital cost due to construction of dam.
(ii) There is uncertainty about the availability of huge amount of water due to dependence on weather conditions.
(iii) Skilled and experienced hands are required to build the plant.
(iv) It requires high cost of transmission lines as the plant is located in hilly areas which are quite away from the consumers.

Schematic Arrangement of Hydro-electric Power Station
Hydro Power Station

Although a hydro-electric power station simply involves the conversion of hydraulic energy into electrical energy, yet it embraces many arrangements for proper working and efficiency. The schematic arrangement of a modern hydro-electric plant is shown in Fig. .

The dam is constructed across a river or lake and water from the catchment area collects at the back of the dam to form a reservoir. A pressure tunnel is taken off from the reservoir and water brought to the valve house at the start of the penstock. The valve house contains main sluice valves and automatic isolating valves. The former controls the water flow to the power house and the latter cuts off supply of water when the penstock bursts. From the valve house, water is taken to water turbine through a huge steel pipe known as penstock. The water turbine converts hydraulic energy into mechanical energy. The turbine drives the alternator which converts mechanical energy into electrical energy.
A surge tank (open from top) is built just before the valve house and protects the penstock from bursting in case the turbine gates suddenly close* due to electrical load being thrown off. When the gates close, there is a sudden stopping of water at the lower end of the penstock and consequently the penstock can burst like a paper log. The surge tank absorbs this pressure swing by increase in its level of water.

Choice of Site for Hydro-electric Power Stations

The following points should be taken into account while selecting the site for a hydro-electric power
station :
(i) Availability of water. Since the primary requirement of a hydro-electric power station is the availability of huge quantity of water, such plants should be built at a place (e.g., river, canal) where adequate water is available at a good head.
(ii) Storage of water. There are wide variations in water supply from a river or canal during the year. This makes it necessary to store water by constructing a dam in order to ensure the generation of power throughout the year. The storage helps in equalising the flow of water so that any excess quantity of water at a certain period of the year can be made available during times of very low flow in the river. This leads to the conclusion that site selected for a hydro-electric plant should provide adequate facilities for erecting a dam and storage of water.
(iii) Cost and type of land.  The land for the construction of the plant should be available at a reasonable price. Further, the bearing capacity of the ground should be adequate to withstand the weight of heavy equipment to be installed.
(iv) Transportation facilities.  The site selected for a hydro-electric plant should be accessible by rail and road so that necessary equipment and machinery could be easily transported. It is clear from the above mentioned factors that ideal choice of site for such a plant is near a river in hilly areas where dam can be conveniently built and large reservoirs can be obtained.

Introduction And Importance To Electrical Energy

 Introduction To Electrical Energy


Energy is the basic necessity for the economic development of a country. Many functions necessary to present-day living grind to halt when the supply of energy stops. It is practically impossible to estimate the
actual magnitude of the part that energy has played in the building up of present-day civilisation. The availability of huge amount of energy in the modern times has resulted in a shorter working day, higher agricultural and industrial production, a healthier and more balanced diet and better transportation facilities.

As a matter of fact, there is a close relationship between the energy used per person and his standard of living. The greater the per capita consumption of energy in a country, the higher is the standard of living of its people.Energy exists in different forms in nature but the most important form is the electrical energy.
The modern society is so much dependent upon the use of electrical energy that it has become a part and parcel of our life. In this chapter, we shall focus our attention on the general aspects of electrical energy.

Importance Of Electrical Energy

Energy may be needed as heat, as light, as motive power etc. The present-day advancement in science and technology has made it possible to convert electrical energy into any desired form. This has given electrical energy a place of pride in the modern world. The survival of industrial undertakings and our social structures depends primarily upon low cost and uninterrupted supply of electrical energy. In fact, the advancement of a country is measured in terms of per capita consumption of electrical energy.

Must Read: Electrical Engineering Interview Questions

Electrical energy is superior to all other forms of energy due to the following reasons :

(i) Convenient form.Electrical energy is a very convenient form of energy. It can be easily converted into other forms of energy. For example, if we want to convert electrical energy into heat, the only thing to be done is to pass electrical current through a wire of high resistance e.g., a heater. Similarly, electrical energy can be converted into light (e.g. electric bulb), mechanical energy (e.g. electric motors) etc.

(ii) Easy control.The electrically operated machines have simple and convenient starting, control and operation. For instance, an electric motor can be started or stopped by turning on or off a switch. Similarly, with simple arrangements, the speed of electric motors can be easily varied over the desired range.

(iii) Greater flexibility.One important reason for preferring electrical energy is the flexibility that it offers. It can be easily transported from one place to another with the help of conductors.

(iv) Cheapness.Electrical energy is much cheaper than other forms of energy. Thus it is overall economical to use this form of energy for domestic, commercial and industrial purposes.

(v) Cleanliness.Electrical energy is not associated with smoke, fumes or poisonous gases. Therefore, its use ensures cleanliness and healthy conditions.

(vi) High transmission efficiency.The consumers of electrical energy are generally situated quite away from the centres of its production. The electrical energy can be transmitted conveniently and efficiently from the centres of generation to the consumers with the help of overhead conductors known as transmission lines.

Friday, 8 May 2015

Factors Affecting Corona Loss

Corona loss depends upon numerous factors like system frequency,
system voltage, air density, surface and size of conductor etc.

These all factors are discribed as follows:-
A. System Frequency :- As we seen the in peeks formula and petersons
formula corona loss directly proportional to the system frequency.

B. System Voltage :- Electric field in the space arround the
conductors depends on potential difference between the conductors.
When potential difference increase the electric field increases and
therefore power loss due to corona increases.

C. Density of Air- Corona loss increases with decrease in air density
that means corona loss inversely proportional to density of air.
Corona loss in a transmission line which passes through a hilly area
than that when same line passes through plains. It is due to reduced
value of delta at high altitudes.

D. Conductivity of Air- Conductivity of air depends on number of ions,
per unit volume of air, size and charge per ion. These factors very
with altitude and atmospheric conditions. It means, in a rainy season,
numbes of ions increases and atmosphere becomes more conducting. When
conductivity increases, corona loss increases.

E. Conductor surface and Conductor Size- Potential gradient at the
surface of stranded conductor is greater than that for equipment solid
conductor, so corona loss is more for stranded conductor. Also corona
loss increases.

F. Load Current- Conductor heats up due to flow of load current.
Heating of conductor prevents the depositions of dew or snow on the
surface of conductor and reduce corona loss. During rains,heating of
conductor has no effect on corona loss, but after rain heating of
conductor accelerates the rate of drying of conductor surface. Time
for which rain drops, remain on surface is reduced and so corona loss
is reduced.

Tuesday, 24 March 2015

Underground Cable Fault Identification Methods

If a fault occurs in the underground cable, it is essential that the type of the fault and location of the fault should be determined as quickly and accurately as possible. Accuracy is important in order to avoid excessive trenching work. The type of fault which is most likely to occur is single conductor to ground fault. In multi-core cables, the fault current will likely give rise to excessive heating at the fault causing further damage to the insulation and extending the fault to remaining conductors. Open circuit faults may occur occasionally which be usually at cable joints. 

Cable fault type identification:

 Prior to the location of the fault on the power system it is important to determine the type of fault so as to make a better choice of the method to be used for fault location
  • Isolate the faulty cable and test each core of the cable for earth fault. One terminal of the insulation tester is earthed and each conductor of the cable is in turn touched with other terminals. If the insulation resistance tester indicates zero resistance during any measurement, conductor to earth fault for the particular conductor is confirmed
  • Then check the insulation resistance between the conductors. In the case it is a short circuit fault, the insulation resistance tester will indicate zero resistance
  • After the above step, short and earth the three conductors of the cable at one end. Check the resistance between the conductors and earth and between individual conductors (at the other end). This procedure is carried out to check the open circuit faults
  • In case in order to test any other faults. the insulation test of the individual cores with sheath or armour and between the cores is essential. The test should also be done by reversing the polarity of the insulation resistance tester. In the case of any difference in the readings, the presence of moisture in the cable insulation is confirmed. The moisture in the cable forms a voltage cell between the lead sheath and conductor because of the difference in the conductivity of these metals and the impregnating compound forms an organic acid when water enters 

Cable fault location Identification:

After the fault type identification, suitable fault location method should be employed to pinpoint the location of the fault. Some of the fault identification methods generally employed are:
  • Murray loop test method
  • Fall of potential test
  • dc charge and discharge method
  • Induction test
  • Impulse wave echo test
  • Time domain reflectometry test

Silicon Carbide (SIC) Lightning Arresters

Silicon Carbide Arresters (SIC):

The Non linear lightning arrester basically consists of set of spark gaps in series with the silicon carbide non linear resistor elements. Lightning arresters are connected between the phase conductors and ground. During normal system operating voltage conditions, the spark gaps are non conducting and isolate the high tension (HT) conductors from the ground. However whenever an overvoltge of magnitude dangerous to the insulation of the apparatus protected occurs ( these over voltages or over surges may be caused due to lightning strikes on the conductors or due to Extra High Voltage (EHV) switching) the spark gap breaks down and allows the high voltage surge current to flow through the ground.

Working Principle of Silicon Carbide (SIC) Lightning Arresters:

The volt-ampere characteristics of the non linear resistor in the lignting arrester can be approximately described by expression V = KIβ. Where K and β are dependent on the composition and manufacturing process of the Non linear Resistor (NLR). The value of β lies generally in the range of 0.3 and 0.45 for modern silicon carbide (SIC) lightning arresters. If the voltage across the Non Linear Resistor (NLR) doubles, the current would increase approximately by 10 times.
Therefore, with multiple spark gaps arresters can withstand high Rate of Recovery Voltage (RRRV). The non-uniform voltage distribution between the gaps (which are in series in lightning arresters) presents a problem. To overcome this, capacitors and non-linear resistors are connected in parallel across each gap. In case of lightning arresters employed for high voltage applications, capacitors and nonlinear resistors are connected across the stock of gaps and NLRs. With the steep voltage wave surge the voltage is mainly controlled by the capacitor and at the power frequency by the non-linear resistors. It is obvious that when the over voltages cause the break down of the series gaps, the current would be very high so as to make the voltage to subside very fast. The highest voltage that appear across the lightning arrester would be either the spark over voltage of the arrester or the voltage developed across the non-linear resistor during the flow of surge current. The lowest spark over voltage of the arrester is called the hundred percent impulse spark over voltage of the arrester. The voltage developed across the non-linear resistor during the flow of surge current is called residual voltage. The lower the value of the voltage developed the better the protection of the lightning arrester.

Disadvantages of Silicon Carbide (SIC) Arresters:

Some of the disadvantages of silicon carbide arresters compared to gapless arresters are given below:
  • Silicon Carbide (SIC) arresters have inferior V-I Characteristics compared to Zno arresters (Metal oxide arresters). 
  • Decrease in energy absorption (surge wave) capability compared to Zno arresters.
  • Probability of sparking between the gaps.  

Advantages of Silicon Carbide (SIC) Arrester :

  • Due to the presence of gaps the normal power frequency voltage during normal operation is negligibly less compared to gap less arresters. Hence no leakage current flow between the line and earth in SIC arresters  

Sunday, 8 March 2015

Electric Energy Generation Utilisation Interview Questions & Answers

Electric Energy Generation Utilisation Interview Questions & Answers

If you are preparing for a technical interview for a lighting systems related products(LED, Lamps etc) company, then you have landed in a correct page. 
This post will serve to refresh the Lighting concepts, illuminations, related laws and important terms. 
Here we had collected some of frequently asked questions related to illumination. 
In addition to that we had added Anna university previous years questions on EEE 8th sem paper Electric Energy Generation Utilisation [Paper code EE1451]. 

[1] Define luminous flux
It is defined as the total quantity of light energy emitted per second from a luminous body. 
  • It is represented by symbol F and is measured in lumens. 
  • The conception of luminous flux helps us to specify the output and efficiency of a given light source.
[2] What is meant by luminance?
It is defined as the luminous per unit projected area of either a surface source of light or a reflecting surface and is denoted by L.

[3] What are the laws of illumination?
Law of Inverse squares
Illumination at a point is inversely proportional to square of its distance from the point source and directly proportional to the luminous intensity (CP) of the source of light in that direction.
  • If a source of light which emits light equally in all directions be placed at the centre of a hollow sphere, the light will fall uniformly on the inner surface of the sphere. 
  • If the sphere be replaced by one of the larger radius, the same total amount of light is spread over a larger area proportional to the square of the radius.
Lamber's cosine law:
The illumination at a point on a surface is proportional to cosine of the angle which ray makes with the normal to the normal to the surface at that point.

[4] What is meant by candle power?
It is defined as the number of lumens given out by the source in a unit solid angle in a given direction. 
It is denoted by CP
Cp = lumens /ω

[5] Define MHCP
The mean of candle power in all directions in the horizontal plane containing the source of light is termed as Mean Horizontal Candle Power

[6] What are all the sources of light?
As per the principle of operation the light sources may be grouped as follows
  1. Arc lamps
  2. High temperature Lamps
  3. Gaseous Discharge Lamps
  4. Fluorescent type Lamps
[7] Define utilisation factor
It is defined as the ratio of total lumens reaching the working plane to total lumens given out by the lamp
utilisation factor  = [Total lumens reaching the working plane] / [Total lumens given out by the lamp]

[8] Name the various photometer heads
  1. Bunsen head or Grease spot photometer
  2. Lummer-brodhun photometer head
There are two types of lummer broadhun heads
  • Equality oc Brightness type photometer head
  • Contrast type photometer head
[9] What is polar curve?

  • In most lamps or sources of light the luminous intensity is not the same in all directions. 
  • If the luminous intensity, ie, the candle power is measured in a horizontal plane about a vertical axis and a curve is plotter between candle power and the angular position, a curve obtained is called as horizontal polar curve.
  • The luminous intensity in all the directions can be represented by polar curves. 
  • If the luminous intensity in a vertical plane is plotted against position, a curve known as vertical polar curve.
[10] Define space-height ratio
It is defined as the ratio of horizontal distance between adjacent lamps and height of their mountings.

Space-height ratio = [Horizontal distance between two adjacent lamps] / [Mounting height of lamps above working plane]

Thanks for reading .... Please leave your comments below....